2045-47-BT1LF

2045-47-BT1LF

J.W. Miller / Bourns

Description

GDT 470V 10KA 2 POLE TH

In Stock: 0

$0.36250

2RP090L-8/B

2RP090L-8/B

Yageo

Description

GDT

In Stock: 0

$0.84000

SL1003A450SM

SL1003A450SM

Wickmann / Littelfuse

Description

GDT 450V 10KA 3 POLE SMD

In Stock: 0

$5.14000

2RM800L-8/B

2RM800L-8/B

Yageo

Description

GDT

In Stock: 0

$1.14000

SH300

SH300

Wickmann / Littelfuse

Description

GDT 300V 5KA 2 POLE SMD

In Stock: 0

$1.59000

2037-15-B

2037-15-B

J.W. Miller / Bourns

Description

GDT 150V 5KA 2 POLE THROUGH HOLE

In Stock: 0

$0.49300

2027-42-CLF

2027-42-CLF

J.W. Miller / Bourns

Description

GDT 420V 10KA 2 POLE TH

In Stock: 0

$0.63800

DSAHR-3

DSAHR-3

Mitsubishi Materials U.S.A

Description

GDT 800V 5KA 2 POLE THROUGH HOLE

In Stock: 10

$54.00000

B88069X0680T502

B88069X0680T502

TDK EPCOS

Description

GDT 255V THROUGH HOLE

In Stock: 313

$3.00000

2036-15-B2LF

2036-15-B2LF

J.W. Miller / Bourns

Description

GDT 150V 10KA 3 POLE TH

In Stock: 435

$2.11000

GTCR37-201M-R10-FS

GTCR37-201M-R10-FS

Wickmann / Littelfuse

Description

GDT 200V 10KA 3 POLE TH

In Stock: 0

$3.20000

2RP600L-8/B

2RP600L-8/B

Yageo

Description

GDT

In Stock: 0

$0.87000

2063-42-ALF

2063-42-ALF

J.W. Miller / Bourns

Description

GDT 420V 60KA 2 POLE

In Stock: 0

$7.78600

2035-35-SM-RPLF

2035-35-SM-RPLF

J.W. Miller / Bourns

Description

GDT 350V 5KA 2 POLE SMD

In Stock: 0

$1.02000

2026-20-C

2026-20-C

J.W. Miller / Bourns

Description

GDT 200V 20KA 3 POLE TH

In Stock: 0

$1.04168

2027-60-CLF

2027-60-CLF

J.W. Miller / Bourns

Description

GDT 600V 10KA 2 POLE TH

In Stock: 922

$1.41000

SL1411A075A

SL1411A075A

Wickmann / Littelfuse

Description

GDT 75V 10KA 2 POLE THROUGH HOLE

In Stock: 419

$2.66000

GTCA25-251M-R02

GTCA25-251M-R02

Wickmann / Littelfuse

Description

GDT 250V 2.5KA 2 POLE TH

In Stock: 0

$2.90000

SL1021A260R

SL1021A260R

Wickmann / Littelfuse

Description

GDT 260V 10KA 3 POLE TH

In Stock: 740

$3.05000

SL1021B350RF

SL1021B350RF

Wickmann / Littelfuse

Description

GDT 350V 20KA 3 POLE TH

In Stock: 0

$6.61000

Gas Discharge Tube Arresters (GDT) for High Surge and Lightning Protection

Gas discharge tube arresters (GDT) are designed to protect electronic systems from high-energy surges and lightning strikes. They provide excellent insulation resistance and high surge current handling capability for demanding environments.

In-Stock GDT Arresters with Fast Delivery

We offer a wide range of GDT arresters with strong inventory and stable sourcing channels. Whether for prototyping or large-scale production, we support fast quotation, no minimum order quantity, and BOM sourcing services. We also assist in sourcing obsolete or hard-to-find components to ensure stable supply.

Product Features and Engineering Advantages

  • High surge current handling capability
  • Excellent insulation resistance and low capacitance
  • Suitable for lightning and overvoltage protection
  • Long service life and high reliability
  • Ideal for telecom, power, and industrial systems
  • In-stock availability with fast global delivery
  • No MOQ required for flexible purchasing
  • Support for small batch and bulk orders
  • BOM quotation and component sourcing services
  • Alternative solutions for discontinued components
  • Original quality with third-party testing support

Applications in Telecom, Power Systems, and Industrial Equipment

GDT arresters are widely used in communication lines, power supply systems, base stations, and industrial equipment to provide reliable protection against lightning and high-energy transient surges.

Quality Assurance and After-Sales Support

All products come with a 180-day warranty. In case of quality issues, customers must provide valid supporting materials such as authorized test reports, images, or videos. Any claims must be submitted within the warranty period. We ensure fast response and effective resolution.

FAQ

1. What is a gas discharge tube (GDT) used for?

GDTs are used to protect circuits from high-energy surges such as lightning strikes and transient overvoltage events.

2. How does a GDT arrester work?

A GDT operates by ionizing gas inside the tube when voltage exceeds a threshold, creating a conductive path to safely divert surge current.

3. What are the advantages of GDT compared to TVS or MOV?

GDTs handle much higher surge currents and provide better isolation, but have slower response times compared to TVS diodes.

4. Where are GDT arresters commonly used?

They are widely used in telecom lines, power systems, industrial equipment, and outdoor installations exposed to lightning risk.

5. Do you support sourcing discontinued GDT components?

Yes, we help source obsolete or hard-to-find GDT arresters and can recommend suitable alternatives.

6. What is your quality assurance policy?

All products come with a 180-day warranty. Customers must provide authorized test reports or visual evidence for any claims within the valid period.

Top