GTCR38-231M-R10-FS

GTCR38-231M-R10-FS

Wickmann / Littelfuse

Description

GDT 230V 10KA 3 POLE TH

In Stock: 0

$3.35000

GTCS25-471M-R02-2

GTCS25-471M-R02-2

Wickmann / Littelfuse

Description

GDT 470V 2.5KA 2 POLE SMD

In Stock: 0

$1.36565

2035-47-B

2035-47-B

J.W. Miller / Bourns

Description

GDT 470V 5KA 2 POLE THROUGH HOLE

In Stock: 0

$0.46400

SL1021B250R

SL1021B250R

Wickmann / Littelfuse

Description

GDT 250V 20KA 3 POLE TH

In Stock: 1 995

$5.75000

2036-09-A

2036-09-A

J.W. Miller / Bourns

Description

GDT 90V 10KA 3 POLE

In Stock: 0

$0.85500

2046-09-ALF

2046-09-ALF

J.W. Miller / Bourns

Description

GDT 90V 10KA 3 POLE

In Stock: 880

$1.38000

CG90LSN

CG90LSN

Wickmann / Littelfuse

Description

GDT 90V 20KA 2 POLE THROUGH HOLE

In Stock: 240

$3.27000

SG350Q

SG350Q

Wickmann / Littelfuse

Description

GDT 350V 1KA 2 POLE SMD

In Stock: 1 940

$1.46000

2056-47-B3LF

2056-47-B3LF

J.W. Miller / Bourns

Description

GDT 470V 5KA 3 POLE THROUGH HOLE

In Stock: 0

$0.65250

2038-47-SM

2038-47-SM

J.W. Miller / Bourns

Description

GDT 470V 5KA 3 POLE SMD

In Stock: 0

$0.96188

2046-09-C2FLF

2046-09-C2FLF

J.W. Miller / Bourns

Description

GDT 90V 10KA 3 POLE THROUGH HOLE

In Stock: 0

$1.09725

B88069X4600C253

B88069X4600C253

TDK EPCOS

Description

GDT 230V 5KA 2 POLE

In Stock: 1 485

$1.15000

B88069X2140T502

B88069X2140T502

TDK EPCOS

Description

GDT 800V 10KA 2 POLE TH

In Stock: 11 408

$2.02000

2056-14-B3LF

2056-14-B3LF

J.W. Miller / Bourns

Description

GDT 145V 5KA 3 POLE THROUGH HOLE

In Stock: 0

$0.65250

GTCN36-351M-R10

GTCN36-351M-R10

Wickmann / Littelfuse

Description

GDT 350V 10KA 3 POLE

In Stock: 0

$5.27000

2027-25-CLF

2027-25-CLF

J.W. Miller / Bourns

Description

GDT 250V 10KA 2 POLE TH

In Stock: 0

$0.63800

2035-40-SM

2035-40-SM

J.W. Miller / Bourns

Description

GDT 400V 5KA 2 POLE SMD

In Stock: 0

$0.44950

2055-60-SM-RPLF

2055-60-SM-RPLF

J.W. Miller / Bourns

Description

GDT 600V 2.5KA 2 POLE SMD

In Stock: 0

$0.35750

GTCS28-750M-R05-2

GTCS28-750M-R05-2

Wickmann / Littelfuse

Description

GDT 75V 5KA 2 POLE SURFACE MOUNT

In Stock: 0

$1.35024

2036-35-B2LF

2036-35-B2LF

J.W. Miller / Bourns

Description

GDT 350V 10KA 3 POLE TH

In Stock: 13

$2.11000

Gas Discharge Tube Arresters (GDT) for High Surge and Lightning Protection

Gas discharge tube arresters (GDT) are designed to protect electronic systems from high-energy surges and lightning strikes. They provide excellent insulation resistance and high surge current handling capability for demanding environments.

In-Stock GDT Arresters with Fast Delivery

We offer a wide range of GDT arresters with strong inventory and stable sourcing channels. Whether for prototyping or large-scale production, we support fast quotation, no minimum order quantity, and BOM sourcing services. We also assist in sourcing obsolete or hard-to-find components to ensure stable supply.

Product Features and Engineering Advantages

  • High surge current handling capability
  • Excellent insulation resistance and low capacitance
  • Suitable for lightning and overvoltage protection
  • Long service life and high reliability
  • Ideal for telecom, power, and industrial systems
  • In-stock availability with fast global delivery
  • No MOQ required for flexible purchasing
  • Support for small batch and bulk orders
  • BOM quotation and component sourcing services
  • Alternative solutions for discontinued components
  • Original quality with third-party testing support

Applications in Telecom, Power Systems, and Industrial Equipment

GDT arresters are widely used in communication lines, power supply systems, base stations, and industrial equipment to provide reliable protection against lightning and high-energy transient surges.

Quality Assurance and After-Sales Support

All products come with a 180-day warranty. In case of quality issues, customers must provide valid supporting materials such as authorized test reports, images, or videos. Any claims must be submitted within the warranty period. We ensure fast response and effective resolution.

FAQ

1. What is a gas discharge tube (GDT) used for?

GDTs are used to protect circuits from high-energy surges such as lightning strikes and transient overvoltage events.

2. How does a GDT arrester work?

A GDT operates by ionizing gas inside the tube when voltage exceeds a threshold, creating a conductive path to safely divert surge current.

3. What are the advantages of GDT compared to TVS or MOV?

GDTs handle much higher surge currents and provide better isolation, but have slower response times compared to TVS diodes.

4. Where are GDT arresters commonly used?

They are widely used in telecom lines, power systems, industrial equipment, and outdoor installations exposed to lightning risk.

5. Do you support sourcing discontinued GDT components?

Yes, we help source obsolete or hard-to-find GDT arresters and can recommend suitable alternatives.

6. What is your quality assurance policy?

All products come with a 180-day warranty. Customers must provide authorized test reports or visual evidence for any claims within the valid period.

Top